I have a question regarding the model SignalGenerator. Running the model in multiple tools result in that we have one state c.v with discontinuous first derivative. The discontinuities wouldn't be a problem if they where associated with events but in this model, there are no event generating expressions. So my question is if this is an appropriate model?
Attached is a figure of the state and state derivative. Notice the jumps in the derivative and that there are no events in this model.
Migrated-From: https://trac.modelica.org/Modelica/ticket/2017