Skip to content

Commit

Permalink
Add support for UWG4 thermostats
Browse files Browse the repository at this point in the history
  • Loading branch information
adamjernst committed Jan 31, 2024
1 parent 8559130 commit 3a82bcf
Show file tree
Hide file tree
Showing 23 changed files with 2,986 additions and 1,454 deletions.
74 changes: 39 additions & 35 deletions README.md
Original file line number Diff line number Diff line change
Expand Up @@ -20,8 +20,7 @@ Asynchronous Python client for communicating with a OJ Microline Thermostat.

## About

A python package with which you control your OJ Microline Thermostat. Currently it supports reading temperatures
and various details about the thermostat(s) and setting the thermostat to another regulation mode.
A Python package to control OJ Microline thermostats. It currently supports the WD5 series (OWD5, MWD5) and WG4 series (UWG4, AWG4).

## Installation

Expand All @@ -33,11 +32,10 @@ pip install ojmicroline-thermostat

### Thermostat

This set represents the current state of your thermostat.
This object represents the current state of a thermostat.

| Variable | Type | Description |
| :------- | :--- | :---------- |
| `thermostat_id` | int | The unique identifier for this thermostat. |
| `model` | string | The model name for this thermostat. |
| `serial_number` | string | The serial number for this thermostat. |
| `software_version` | string | The currently installed software version. |
Expand All @@ -46,37 +44,56 @@ This set represents the current state of your thermostat.
| `name` | string | The name of the thermostat. |
| `online` | boolean | Indicates if the thermostat is connected to the network. |
| `heating` | boolean | Indicates if the thermostat is currently heating/is on. |
| `regulation_mode` | integer | The currently set regulation mode of the thermostat, see below. |
| `supported_regulation_modes` | list | The regulation modes this thermostat supports. |
| `min_temperature` | integer | The lowest temperature the thermostat can be set to. |
| `max_temperature` | integer | The highest temperature the thermostat can be set to. |
| `manual_temperature` | integer | If the regulation mode is set to manual mode, the thermostat will target this temperature. |
| `comfort_temperature` | integer | If the regulation mode is set to comfort mode, the thermostat will target this temperature. |
| `comfort_end_time` | datetime | If the regulation mode is set to comfort mode, it will end at this time. |
| `last_primary_mode_is_auto` | boolean | Unknown |

These fields are only available on WD5-series thermostats; for others, they may be `None`:

| Variable | Type | Description |
| :------- | :--- | :---------- |
| `thermostat_id` | int | The unique identifier for this thermostat. |
| `adaptive_mode` | boolean | If on then then the thermostat automatically changes heating start times to ensure that the required temperature has been reached at the beginning of any specific event. |
| `vacation_mode` | boolean | If on then the thermostat regulates the heating of your home to a minimum while you are away on holiday, thus saving energy and money. |
| `open_window_detection` | boolean | If on then the thermostat shuts off the heating for 30 minutes if an open window is detected. |
| `last_primary_mode_is_auto` | boolean | Unknown |
| `daylight_saving_active` | boolean | If on, the "Daylight Saving Time" function of the thermostat will automatically adjust the clock to the daylight saving time for the "Region" chosen. |
| `regulation_mode` | integer | The currently set regulation mode of the thermostat, see below. |
| `sensor_mode` | integer | The currently set sensor mode of the thermostat, see below. |
| `temperature_floor` | integer | The temperature measured by the floor. sensor |
| `temperature_floor` | integer | The temperature measured by the floor sensor. |
| `temperature_room` | integer | The temperature measured by the room sensor. |
| `min_temperature` | integer | The minimum set temperature for the thermostat. |
| `max_temperature` | integer | The maximum set temperature for the thermostat. |
| `temperatures` | object | The currently set temperatures for each regulation mode, see below. |
| `boost_temperature` | integer | If the regulation mode is set to boost mode, the thermostat will target this temperature. |
| `boost_end_time` | datetime | If the regulation mode is set to boost mode, it will end at this time. |
| `comfort_end_time` | datetime | If the regulation mode is set to comfort mode, it will end at this time. |
| `vacation_temperature` | integer | If the regulation mode is set to vacation mode, the thermostat will target this temperature. |
| `vacation_begin_time` | datetime | Vacation mode will be set to on when this date time passes. |
| `vacation_end_time` | datetime | Vacation mode will be set to off when this date time passes. |
| `offset` | integer | The offset (timezone) set by the thermostat. |
| `schedule` | Schedule | The schedule the thermostat currently uses. |
| `frost_protection_temperature` | integer | If the regulation mode is set to frost protection mode, the thermostat will target this temperature. |
| `schedule` | Schedule | The schedule the thermostat currently uses. (This *could* be supported by WG4-series thermostats, it simply isn't implemented.) |

These fields are only available on WG4-series thermostats; for others, they may be `None`:

| Variable | Type | Description |
| :------- | :--- | :---------- |
| `temperature` | integer | The current temperature; the thermostat uses the room sensor or floor sensor based on its configuration. Avoid using this directly; instead, call the `get_current_temperature()` method which also works for WD5-series thermostats. |
| `set_point_temperature` | integer | The temperature the thermostat is targeting. Avoid using this directly; instead, call the `get_target_temperature()` method which also works for WD5-series thermostats. |

#### Regulation modes

| Integer | Constant | Description |
| :------- | :--- | :---------- |
| `1` | `REGULATION_SCHEDULE` | The thermostat follows the configured schedule. |
| `2` | `REGULATION_COMFORT` | The thermostat is in comfort mode for the next 4 hours. |
| `2` | `REGULATION_COMFORT` | The thermostat is in comfort mode until `comfort_end_time`. |
| `3` | `REGULATION_MANUAL` | The thermostat is in manual mode, will not resume schedule unless changed. |
| `4` | `REGULATION_VACATION` | The thermostat is in vacation mode, it started at `vacation_begin_time` and ends at `vacation_end_time`. |
| `6` | `REGULATION_FROST_PROTECTION` | The thermostat is set to frost protection, preventing the floor from freezing. |
| `8` | `REGULATION_BOOST` | The thermostat is in boost mode for 1 hour, using the `max_temperature` as target temperature. |
| `9` | `REGULATION_ECO` | The thermostat is in eco mode, using the lowest temperature of the `schedule`. |

Keep in mind that certain thermostats only support a subset of these modes; be sure to check the `Thermostat.supported_regulation_modes` field.

#### Sensor modes

| Integer | Constant | Description |
Expand All @@ -92,15 +109,15 @@ This set represents the current state of your thermostat.
| :------- | :--- | :---------- |
| `login` | `None` | Create a new session at the OJ Microline API. |
| `get_thermostats` | `None` | Get all thermostats from the OJ Microline API. |
| `set_regulation_mode` | `resource: Thermostat`, `regulation_mode: int`, `temperature: int \| None = None` | Set the regulation mode based on the input.<br> - `resource`: An instance of a Thermostat model returned by `get_thermostats()`<br> - `regulation_mode`: An integer representing the regulation mode, see "Regulation modes"<br> - `temperature`: An integer representing the temperature, eg: 2500. Only useful when setting the regulation mode to manual or comfort. |
| `set_regulation_mode` | `resource: Thermostat`, `regulation_mode: int`, `temperature: int \| None = None`, `duration: int = COMFORT_DURATION` | Set the regulation mode based on the input.<br> - `resource`: An instance of a Thermostat model returned by `get_thermostats()`<br> - `regulation_mode`: An integer representing the regulation mode, see "Regulation modes"<br> - `temperature`: An integer representing the temperature, eg: 2500. Only useful when setting the regulation mode to manual or comfort.<br> - `duration`: The duration in minutes to set the temperature for; only applies to comfort mode. |

## Usage

```python
import asyncio
from time import sleep

from ojmicroline_thermostat import OJMicroline, Thermostat
from ojmicroline_thermostat import OJMicroline, Thermostat, WD5API
from ojmicroline_thermostat.const import (
REGULATION_BOOST,
REGULATION_COMFORT,
Expand All @@ -109,9 +126,6 @@ from ojmicroline_thermostat.const import (
REGULATION_MANUAL,
REGULATION_SCHEDULE,
REGULATION_VACATION,
SENSOR_FLOOR,
SENSOR_ROOM,
SENSOR_ROOM_FLOOR,
)

REGULATION_MODES = {
Expand All @@ -124,21 +138,16 @@ REGULATION_MODES = {
REGULATION_VACATION: "Vacation",
}

SENSOR_MODES = {
SENSOR_FLOOR: "Floor",
SENSOR_ROOM: "Room",
SENSOR_ROOM_FLOOR: "Room/Floor",
}


async def main():
"""Show example on using the OJMicroline client."""
async with OJMicroline(
host="ocd5.azurewebsites.net",
customer_id=1234,
api_key="<app-api-key>",
username="<your-username>",
password="<your-password>",
api=WD5API(
customer_id=1234,
api_key="<app-api-key>",
username="<your-username>",
password="<your-password>",
),
) as client:
# Thermostats
thermostats: list[Thermostat] = await client.get_thermostats()
Expand All @@ -149,14 +158,9 @@ async def main():
print("####################")
print("- Details:")
print(f" Serial Number: {resource.serial_number}")
print(f" Sensor mode: {SENSOR_MODES[resource.sensor_mode]}")
print("- Regulation:")
print(f" Mode: {REGULATION_MODES[resource.regulation_mode]}")
print(f" Temperature: {resource.get_current_temperature()}")
print(f" Target temperature: {resource.get_target_temperature()}")
print("- Temperatures:")
print(f" Floor: {resource.temperature_floor}")
print(f" Room: {resource.temperature_room}")
print("")

print(f"- Setting to boost mode")
Expand Down
4 changes: 4 additions & 0 deletions ojmicroline_thermostat/__init__.py
Original file line number Diff line number Diff line change
Expand Up @@ -9,6 +9,8 @@
)
from .models import Thermostat
from .ojmicroline import OJMicroline
from .wd5 import WD5API
from .wg4 import WG4API

__all__ = [
"Thermostat",
Expand All @@ -18,4 +20,6 @@
"OJMicrolineConnectionException",
"OJMicrolineResultsException",
"OJMicrolineTimeoutException",
"WD5API",
"WG4API",
]
3 changes: 2 additions & 1 deletion ojmicroline_thermostat/const.py
Original file line number Diff line number Diff line change
Expand Up @@ -11,5 +11,6 @@
REGULATION_BOOST = 8
REGULATION_ECO = 9

DATETIME_FORMAT = "%Y-%m-%dT%H:%M:%S"
WD5_DATETIME_FORMAT = "%Y-%m-%dT%H:%M:%S"
WG4_DATETIME_FORMAT = "%d/%m/%Y %H:%M:%S %z"
COMFORT_DURATION = 240
Loading

0 comments on commit 3a82bcf