Notifications
You must be signed in to change notification settings - Fork 305
/
Copy path08.hmu.csv
We can make this file beautiful and searchable if this error is corrected: Illegal quoting in line 105.
225 lines (223 loc) · 17.7 KB
/
08.hmu.csv
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
# type (r[1-9];w;u),circuit,name,[comment],[QQ],ZZ,PBSB,[ID],field1,part (m/s),datatypes/templates,divider/values,unit,comment,field2,part (m/s),datatypes/templates,divider/values,unit,comment,field3,part (m/s),datatypes/templates,divider/values,unit,comment,field4,part (m/s),datatypes/templates,divider/values,unit,comment
*r,,,,,,"B511",,,,,,,,,,,,,,,,,,,,,,,,,
r,,State,,,,,07,energy,,UCH,,,,,,energy,,,,,,onoff,,,,state,,UCH,0x01=ready;0x0b=error;0x09=heating;0x11=cooling;0x81=heating_water,,
# Heatpump statistics,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
*r,,,,,,"B51A","05FF32",,,IGN:3,,,,,,,,,,,,,,,,,,,,,
r,,YieldHcDay,,,,,00,,,energy,10,kWh,,,,,,,,,,,,,,,,,,,
r,,YieldCoolDay,,,,,01,,,energy,10,kWh,,,,,,,,,,,,,,,,,,,
r,,YieldHwcDay,,,,,02,,,energy,10,kWh,,,,,,,,,,,,,
r,,YieldHcMonth,,,,,0e,,,energy,10,kWh,,,,,,,,,,,,,
r,,CopHcMonth,,,,,0f,,,UIN,10,,,,,,,,,,,,,,
r,,YieldHc,,,,,10,,,energy,,kWh,,,,,,,,,,,,,
r,,CopHc,,,,,11,,,UIN,10,,,,,,,,,,,,,,
r,,YieldHwcMonth,,,,,12,,,energy,10,kWh,,,,,,,,,,,,,
r,,CopHwcMonth,,,,,13,,,UIN,10,,,,,,,,,,,,,,
r,,YieldHwc,energy yield hot water,,,,16,,,energy4,,,,,,,,,,,,,,,,,,,,,
r,,CopHwc,,,,,17,,,UIN,10,,,,,,,,,,,,,,
r,,Hours,operation hours,,,,40,,,hoursum,,,,,,,,,,,,,,,,,,,,,
r,,HoursHc,operation hours heating,,,,41,,,hoursum,,,,,,,,,,,,,,,,,,,,,
r,,HoursCool,operation hours cooling,,,,43,,,hoursum,,,,,,,,,,,,,,,,,,,,,
r,,HoursHwc,operation hours hot water,,,,44,,,hoursum,,,,,,,,,,,,,,,,
# some more statistics from Live Monitor,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
r,,TargetFlowTemp,target flow temperature,,,,1F,,,temp,,,,,,,,,,,,,,,,,,,,,
r,,FlowTemp,current flow temperature,,,,20,,,temp,,,,,,,,,,,,,,,,,,,,,
r,,EnergyIntegral,current energy integral,,,,21,,,integral,,,,,,,,,,,,,,,,,,,,,
# example: 3108b51a0405ff3223 / 0aff083500000000000000
r,,CurrentYieldPower,current yielded energy from the environment,,,,23,,,D1B,10,kW,,,,,,,,,,,,,,,,,,,
# example: 3108b51a0405ff3224 / 0aff083501000000000000
r,,CurrentConsumedPower,current power consumption,,,,24,,,D1B,10,kW,,,,,,,,,,,,,,,,,,,
r,,CurrentCompressorUtil,current compressor utilization,,,,25,,,D1B,,%,,,,,,,,,,,,,,,,,,,
r,,AirIntakeTemp,air intake temperature,,,,26,,,temp,,,,,,,,,,,,,,,
# Values from Live Monitor,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
r,,TargetTempHc,heat circuit target temperature,,,,1C,,,D2C,,°C,,,,,,,,,,,,,
r,,SourceTempOutput,,,,,27,,,D2C,,°C,,,,,,,,,,,,,
r,,BuildingCircuitFlow,,,,,3C,,,UIN,,l/h,,,,,,,,,,,,,
r,,FlowPressure,,,,,3d,,,D2C,4,,,,,,,,,,,,,,
r,,SourcePressure,,,,,3e,,,D2C,4,,,,,,,,,,,,,,
# example: 3108b51a0405ff324d / 02ff01 (not working!)
r,,TotalEnergyUsage,,,,,4D,,,energy,,kWh,,,,,,,,,,,,,
*r,,,,,,"B51A","05FF34",,,IGN:3,,,,,,,,,,,,,,,,,,,,,
# TODO ff34 prefix also seen as e534 in PR 330, see also duplication in StatCompressorHours with b434 and others. this seems to be HW/SW specific and needs to be sorted out.
*u,,,,,,"B51A","05E534",,,IGN:3,,,,,,,,,,,,,,,,,,,,,
r;u,,CompressorHours,,,,,00,,,UIN,,h,hours,,,,,,,,,,,,,
r;u,,CompressorStarts,,,,,01,,,UIN,,,,,,,,,,,,,,,
r;u,,BuildingPumpHours,,,,,02,,,UIN,,h,hours,,,,,,,,,,,,,
r;u,,BuildingPumpStarts,,,,,03,,,UIN,,,,,,,,,,,,,,,
r;u,,ForWayValveHours,,,,,06,,,UIN,,h,hours,,,,,,,,,,,,,
r;u,,ForWayValveSwitches,,,,,07,,,UIN,,,,,,,,,,,,,,,
r;u,,EEVSteps,,,,,0D,,,UIN,,,,,,,,,,,,,,,
r;u,,FourWayValveSwitchingOperations,,,,,30,,,UIN,,,,,,,,,,,,,,,
r;u,,Fan1Hours,,,,,51,,,UIN,,h,hours,,,,,,,,,,,,,
r;u,,Fan1Starts,,,,,52,,,UIN,,,,,,,,,,,,,,,
r;u,,Fan2Hours,,,,,5E,,,UIN,,h,hours,,,,,,,,,,,,,
r;u,,Fan2Starts,,,,,5F,,,UIN,,,,,,,,,,,,,,,
# Heat pump configuration menu values
r,,HeatCurve,,,,,8F352D,,,IGN:3,,,,,,BCD,10,,heat curve 0.1 to 4.0,,,,,,,,,,,,
r,,SummerSwitchOffTemp,,,,,8F352E,,,IGN:3,,,,,,D2C,,°C,Switch-off temperature summer (°C),,,,,,,,,,,,
r,,HcBivalencePoint,,,,,8F352F,,,IGN:3,,,,,,D2C,,°C,Central heating bivalence point (°C),,,,,,,,,,,,
r,,HwcBivalencePoint,,,,,8F3530,,,IGN:3,,,,,,D2C,,°C,Bivalence point domestic hot water (°C),,,,,,,,,,,,
r,,MaxFlowTemp,,,,,8F3532,,,IGN:3,,,,,,D2C,,°C,Maximum flow temperature (°C),,,,,,,,,,,,
r,,MinFlowTemp,,,,,8F3533,,,IGN:3,,,,,,D2C,,°C,Minimum flow temperature (°C),,,,,,,,,,,,
r,,HcModeActive,,,,,8F3534,,,IGN:3,,,,,,UCH,0=no;1=yes,,Central heating mode active (yes/no),,,,,,,,,,,,
r,,HwcModeActive,,,,,8F3535,,,IGN:3,,,,,,UCH,0=no;1=yes,,Domestic hot water mode active (yes/no),,,,,,,,,,,,
r,,HwcChargeHysteresis,,,,,8F3539,,,IGN:3,,,,,,D2C,,°K,Hysteresis Hwc charging (°K),,,,,,,,,,,,
r,,ImmersionHeaterMode,,,,,C4331E,,,IGN:3,,,,,,UCH,0=off;1=on,,Immersion heater mode (on/off),,,,,,,,,,,,
r,,CompressorHysteresisHc,,,,,F83443,,,IGN:3,,,,,,D2C,,°K,Compressor hysteresis central heating (°K),,,,,,,,,,,,
r,,CompressorHysteresisCooling,,,,,86353F,,,IGN:3,,,,,,D2C,,,Compressor hysteresis cooling (°K),,,,,,,,,,,,
r,,HwcMode,,,,,523444,,,IGN:3,,,,,,UCH,0=eco;1=normal;2=balance,,Domestic hot water mod (eco/normal/balance),,,,,,,,,,,,
r,,TargetTempHwc,,,,,C63207,,,IGN:3,,,,,,D2C,,°C,Target Hwc temperature (°C),,,,,,,,,,,,
# Total heating yields,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
*r,,,,,,"B516","18",,,IGN:1,,,,,,,,,,,,,,,,,,,,,
r,,YieldTotal,,,,,01,,,energy,,,,,,,,,,,,,,,,,,,,,
# Total electric power consumption,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
r,,ConsumptionTotal,,,,,02,,,energy,,,,,,,,,,,,,,,,,,,,,
# Ecologic energy Yields,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
*r,,,,,,"B516","1A01",,,IGN:1,,,,,,,,,,,,,,,,,,,,,
r,,YieldThisYear1,,,,,0100,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,,
r,,YieldThisYear2,,,,,0200,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,,
r,,YieldThisYear3,,,,,0300,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,,
r,,YieldThisYear4,,,,,0400,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,,
r,,YieldThisYear5,,,,,0500,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,,
r,,YieldThisYear6,,,,,0600,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,,
r,,YieldThisYear7,,,,,0700,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,,
r,,YieldThisYear8,,,,,0800,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,,
r,,YieldThisYear9,,,,,0900,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,,
r,,YieldThisYear10,,,,,0A00,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,,
r,,YieldThisYear11,,,,,0B00,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,,
r,,YieldThisYear12,,,,,0C00,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,,
# Electric power consumption,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
*r,,,,,,"B516","1A02",,,IGN:1,,,,,,,,,,,,,,,,,,,,,
r,,ConsumptionThisYear1,,,,,0100,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,,
r,,ConsumptionThisYear2,,,,,0200,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,,
r,,ConsumptionThisYear3,,,,,0300,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,,
r,,ConsumptionThisYear4,,,,,0400,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,,
r,,ConsumptionThisYear5,,,,,0500,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,,
r,,ConsumptionThisYear6,,,,,0600,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,,
r,,ConsumptionThisYear7,,,,,0700,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,,
r,,ConsumptionThisYear8,,,,,0800,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,,
r,,ConsumptionThisYear9,,,,,0900,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,,
r,,ConsumptionThisYear10,,,,,0A00,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,,
r,,ConsumptionThisYear11,,,,,0B00,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,,
r,,ConsumptionThisYear12,,,,,0C00,month,,D1B,,,,,,IGN:1,,,,,,energy,,,,,,,,,
# additions from PR 160 for HMU;0304;8802;0010019765
# Test menus on VWZ. EnableTest message needs to be sent before each of the read messages work.,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
*rs,#service,,,,,"B514",05,,,IGN:2,,,,,,,,,,,,,,,,,,,,,
*ws,#service,,,,,"B514",05,ignore,m,HEX:3,="03FFFF",,,,,,,,,,,,,,,,,,,,
ws,,EnableTestEEVPosition,read EEV position,,,,15
rs,,TestEEVPosition,EEV position,,,,15,,,percent0,,,T.0.21
ws,,EnableTestCompressorExitTemp,read compressor outlet temperature,,,,37
rs,,TestCompressorExitTemp,compressor outlet temperature,,,,37,,,SIN,10,°C,T.0.55
ws,,EnableTestCompressorIntakeTemp,read compressor inlet temperature,,,,38
rs,,TestCompressorInletTemp,compressor inlet temperature,,,,38,,,SIN,10,°C,T.0.56
ws,,EnableTestWaterThroughput,read current heating water flow rate,,,,2B
rs,,TestWaterThroughput,current heating water flow rate,,,,2B,,,UIN,,l/h,T.0.45
ws,,EnableTestCompressorSpeed,read compressor speed,,,,5D
rs,,TestCompressorSpeed,compressor speed,,,,5d,,,SIN,10,U/s,T.0.93
# installer level test menu sensor/actor test from PR #174
rs,,TestBuildingPumpPower,building pump power,,,,01,,,percent0,,,T.0.01
rs,,TestFan1,fan 1,,,,11,,,percent0,,,T.0.02
rs,,TestFan2,fan 2,,,,12,,,percent0,,,T.0.02
rs,,TestCondensateTrayHeater,condensate tray heater,,,,13,,,onoff,,,T.0.19
rs,,TestFourWayValve,4 way valve,,,,14,,,onoff,,,T.0.20
rs,,TestHeatingCoilCompressor,heating coil compressor,,,,17,,,onoff,,,T.0.23
ws,,EnableTestFlowTemp,read flow temperature,,,,28
rs,,TestFlowTemp,flow temperature,,,,28,,,SIN,10,°C,T.0.40
ws,,EnableTestReturnTemp,read return temperature,,,,29
rs,,TestReturnTemp,return temperature,,,,29,,,SIN,10,°C,T.0.41
rs,,TestBuildingWaterPress,building water pressure,,,,2a,,,UIN,10,bar,T.0.42
rs,,TestAirIntakeTemp,air intake temperature,,,,30,,,SIN,10,°C,T.0.48
rs,,TestEEVOutletTemp,EEV outlet temperature,,,,39,,,SIN,10,°C,T.0.57
rs,,TestCondensorOutletTemp,condensor outlet temperature,,,,3b,,,SIN,10,°C,T.0.59
ws,,EnableTestHighPress,read high pressure,,,,3f
rs,,TestHighPress,high pressure,,,,3f,,,SIN,10,bar,T.0.63
rs,,TestLowPress,low pressure,,,,40,,,SIN,10,bar,T.0.64
rs,,TestHighPressureSwitch,high pressure switch,,,,43,,,UCH,0=open;1=close,,T.0.67
ws,,EnableTestEvaporationTemp,read evaporation temperature,,,,55
rs,,TestEvaporationTemp,evaporation temperature,,,,55,,,SIN,10,°C,T.0.85
ws,,EnableTestCondensateTemp,read condensate temperature,,,,56
rs,,TestCondensateTemp,condensate temperature,,,,56,,,SIN,10,°C,T.0.86
rs,,TestOverheatingTargetValue,overheating target value,,,,57,,,SIN,10,K,T.0.87
rs,,TestOverheatingActualValue,overheating current value,,,,58,,,SIN,10,K,T.0.88
rs,,TestSubcoolingTargetValue,sub cooling target value,,,,59,,,SIN,10,K,T.0.89
rs,,TestSubcoolingActualValue,sub cooling current value,,,,5a,,,SIN,10,K,T.0.90
rs,,TestTempSwitchCompressorOutlet,temperature switch compressor outlet,,,,7b,,,UCH,0=open;1=close,,T.0.123
rs,,TestPrioritySwitchingValve,priority switch valve WW,,,,02,,,switchvalve,,,T.1.02
rs,,TestCylinderTemp,storage temperature,,,,2c,,,SIN,10,°C,T.1.44
rs,,TestLockoutContactS20,lockout contact S20,,,,2e,,,UCH,0=close;1=open,,T.1.46
rs,,TestOutdoorTemp,outside temperature,,,,45,,,SIN,10,°C,T.1.69
rs,,TestSystemTemp,system temperature,,,,46,,,SIN,10,°C,T.1.70
rs,,TestDCFStatus,DCF status,,,,47,,,dcfstate,,,T.1.71
rs,,TestLockoutContactS21,lockout contact S21,,,,48,,,UCH,0=close;1=open,,T.1.72
rs,,TestMA1Output,MA1 output,,,,77,,,onoff,,,T.1.119
rs,,TestImmersionHeaterSafetyCutOut,STB heater,,,,7c,,,UCH,0=close;1=open,,T.1.124
rs,,TestMIInput,ME input,,,,7d,,,SIN,,,T.1.125
rs,,TestMO2Output,MA2 output,,,,7e,,,onoff,,,T.1.126
rs,,TestMO3Output,MA3 output,,,,7f,,,onoff,,,T.1.127
rs,,TestCondensorInletTemp,condensor inlet temperature,,,,81,,,SIN,10,°C,
rs,,TestFlowTempImmersionHeater,Vorlauftemperatur Heizstab,,,,82,,,SIN,10,°C,T1.130
*rs,#service,,,,,"B514",05,,,IGN:2,,,,,,,,,,,,,,,,,,,,,
*ws,#service,,,,,"B514",05,ignore,,HEX:3,="000000",,,,,,,,,,,,,,,,,,,,
ws,,EnableTestEEVTemp,read EEV temperature,,,,3b,,m,HEX:3
rs,,TestEEVTemp,EEV temperature,,,,3b000000,,,IGN:2,,,,,,SIN,10,,°C
# Values from Live Monitor. EnableLiveMonitorMain message needs to be sent before the read message works.,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
*us,#service,,,,,B503,00,,,,,,,,,,,,,,,,,,,,,,,,
*ws,#service,,,,,B503,00,,,,,,,,,,,,,,,,,,,,,,,,
ws,,EnableiveMonitorMain,enable live monitor read status,,,,03,,,,,,,,,,,,,,,,,,,,,,,,,
# example: 244;Heating 3108b503020003 / 0af401ffffffffffffffff
us,,LiveMonitorMain,live monitor status,71,,,03,status,,UCH,0x39=Controller starting;0xf4=Standby;0xf5=Supply on;0xf6=Heating: Flow ok;0xf7=Heating: temperature self test;0xf8=Heating: Start;0xfa=Heating: Fan on;0xfc=EEV switch;0xfd=Compressor starting;0xfe=Heating: compressor on;0x00=Compressor off;0x02=Compressor coast down;0x03=Deicing start;0x04=Deicing;0x05=Deicing end;0x12=Cooling: Flow on;0x14=Cooling: temperature self test;0x15=Cooling: starting;0x17=Cooling: Fan on;0x13=Cooling: Flow ok;0x19=Cooling: EEV?;0x1a=Cooling: compressor starting;0x1b=Cooling: compressor on;0x1d=Cooling: ending;0x29=Start condition not met;0x57=Device error;0x44=Flow error in distribution system,,,function,,UCH,0x01=Heating;0x02=Cooling,,,,,,,,,,,,,,
*rs,#service,,,,,B51A,050032,,,IGN:3,,,,,,,,,,,,,,,,,,,,,
# example: 3108b51a040500321f / 0a000805f0000000000000
rs,,LiveMonitorDesiredSupplyTemp,desired supply temperature,,,,1f,,,temp,,,,,,,,,,,,,,,
# example: 3108b51a0405003220 / 0a0008081b010000000000
rs,,LiveMonitorCurrentSupplyTemp,current supply temperature,,,,20,,,temp,,,,,,,,,,,,,,,
# example:108b51a0405003223 / 0a00083500000000000000
rs,,LiveMonitorCurrentYieldPower,current power generated,,,,23,,,UIN,10,kW,,,,,,,,,,,,,
# example: 3108b51a0405003224 / 0a00083500000000000000
rs,,LiveMonitorCurrentConsumedPower,current power consumption,,,,24,,,UIN,10,kW,,,,,,,,,,,,,
#example:08b51a0405003225 / 0a00081b00000000000000
rs,,LiveMonitorCurrentCompressorUtil,compressor modulation,,,,25,,,D1B,,%,,,,,,,,,,,,,
# example: 3108b51a0405003226 / 0a000808df000000000000
rs,,LiveMonitorAirIntakeTemp,air intake temperature,,,,26,,,temp,,,,,,,,,,,,,,,
# installer level test menu statistics from PR #174
*ri,#install,,,,,"B51A","05",,,IGN:3,,,,
ri,,StatCompressorHours,compressor hours,,,,b43400,,,hoursum,,,
ri,,StatCompressorStarts,compressor starts,,,,b43401,,,UIN,,,
ri,,StatBuildingPumpHours,building punp hours,,,,b43402,,,hoursum,,,
ri,,StatBuildingPumpStarts,building punp starts,,,,b43403,,,UIN,,,
ri,,StatFourWayValveHours,4 way valve hours,,,,073406,,,hoursum,,,
ri,,StatFourWayValveSwitchingOperations,4 way valve switching operations,,,,363407,,,UIN,,,
ri,,StatFan1Hours,fan 1 hours,,,,3c3451,,,hoursum,,,
ri,,StatFan1Starts,fan 1 starts,,,,d63452,,,UIN,,,
ri,,StatEEVSteps,EEV steps,,,,e4340d,,,UIN,,,
# stats from PR 407, potentially for HW5103+SW0607 only
*r,,,,,,B509,540200,,,IGN:4,,,,,,,,,,,,,,,,,,,,,
r,,RunDataCompressorSpeed,,,,,0D0A,,,EXP,,rps,,,,,,,,,,,,,,,,,,,
r,,RunDataEEVPositionAbs,(EEV Position in different scale?),,,,280A,,,UIN,,,,,,,,,,,,,,,,,,,,,
r,,RunDataFan1Speed,,,,,470A,,,EXP,,rpm,,,,,,,,,,,,,,,,,,,
r,,RunDataFan2Speed,,,,,490A,,,EXP,,rpm,,,,,,,,,,,,,,,,,,,
r,,RunDataStatuscode,,,,,530D,,,UIN,34=Frost protection;100=Standby;101=Heating: Compressor shutdown;102=Heating: Compressor blocked;103=Heating: Prerun;104=Heating: Compressor active;107=Heating: Overrun;111=Cooling: Compressor shutdown;112=Cooling: Compressor blocked;113=Cooling: Prerun;114=Cooling: Compressor active;117=Cooling: Overrun;125=Heating: Immersion heater active;132=Warm Water: Compressor blocked;133=Warm Water: Prerun;134=Warm Water: Compressor active;135=Warm Water: Immersion Heater active;137=Warm Water: Overrun;141=Heating: Immersion Heater shutdown;142=Heating: Immersion Heater blocked;151=Warm Water: Immersion Heater shutdown;152=Warm Water: Immersion Heater blocked;202=Air purging program active;240=Compressor oil heating activated;252=Fan 1 blocked;255=Fan 1 air inlet too high;256=Fan 1 air inlet too low;260=Fan 2 blocked;275=Building circuit flow too low;277=Building circuit pump fault;280=Frequency converter fault: Compressor;281=Frequency converter fault: Mains voltage;282=Frequency converter fault: Overheating;283=Deicing time too long;284=Deicing flow temperature too low;285=Compressor outlet temperature too high;286=Hot gas temperature switch open;287=Fan 1: Wind;288=Fan 2: Wind;289=Current limt active;302=High pressure switch open;303=Compressor outlet temperature too high;304=Evaporation temperature too low;305=Condensation temperature too low;306=Evaporation temperature too high;308=Condensation temperature too high;312=Building circuit return temperature too low;314=Building circuit return temperature too high;351=Immersion heater: Flow temperature too high;516=Deicing active;575=Frequency converter fault;581=Connection fault: frequency converter;590=4-port-valve position fault,,,,,,,,,,,,,,,,,,,,
r,,RunDataElectricPowerConsumption,,,,,5B0D,,,EXP,,W,current electrical power consumption (Watt),,,,,,,,,,,,,,,,,,
r,,RunDataHighPressure,,,,,6A09,,,pressv,,,,,,,,,,,,,,,,,,,,,
r,,RunDataCompressorInletTemp,,,,,9808,,,tempv,,,,,,,,,,,,,,,,,,,,,
r,,RunDataCompressorOutletTemp,,,,,A208,,,tempv,,,,,,,,,,,,,,,,,,,,,
r,,RunDataEEVOutletTemp,,,,,AC08,,,tempv,,,,,,,,,,,,,,,,,,,,,
r,,RunStatsHMUHours,,,,,B80B,,,UIN,,hours,,,,,,,,,,,,,,,,,,,
r,,RunStatsHcHours,,,,,B90B,,,UIN,,hours,,,,,,,,,,,,,,,,,,,
r,,RunStatsHwcHours,,,,,BC0B,,,UIN,,hours,total runtime of Hwc mode,,,,,,,,,,,,,,,,,,
r,,RunStatsCompressorHours,,,,,C20B,,,UIN,,hours,,,,,,,,,,,,,,,,,,,
r,,RunStatsCompressorStarts,,,,,C30B,,,cntstarts2,,,,,,,,,,,,,,,,,,,,,
r,,RunStatsBuildingPumpHours,,,,,C40B,,,UIN,,hours,,,,,,,,,,,,,,,,,,,
r,,RunDataBuildingCPumpPower,,,,,C509,,,EXP,,%,,,,,,,,,,,,,,,,,,,
r,,RunStatsBuildingCPumpStarts,,,,,C50B,,,cntstarts2,,,total starts of building circuit pump,,,,,,,,,,,,,,,,,,
r,,RunStats4PortValveHours,,,,,C80B,,,UIN,,hours,,,,,,,,,,,,,,,,,,,
r,,RunStats4PortValveSwitches,,,,,C90B,,,cntstarts2,,,,,,,,,,,,,,,,,,,,,
r,,RunStatsFan1Hours,,,,,D70B,,,UIN,,hours,,,,,,,,,,,,,,,,,,,
r,,RunStatsFan1Starts,,,,,D80B,,,cntstarts2,,,,,,,,,,,,,,,,,,,,,
r,,RunStatsFan2Hours,,,,,D90B,,,UIN,,hours,,,,,,,,,,,,,,,,,,,
r,,RunStatsFan2Starts,,,,,DA0B,,,cntstarts2,,,,,,,,,,,,,,,,,,,,,
r,,RunDataAirInletTemp,,,,,DE08,,,tempv,,,,,,,,,,,,,,,,,,,,,
*r,,,,,,"B511",,,,,,,,,,,,,,,,,,,,,,,,,
r,,RunStatsCompressorHc,compressor runtime in min and starts in Hc mode,,,,1801,,,IGN:1;minutes4:runtime;cntstarts:cycles,,,,,,,,,,,,,,,,,,,,,
r,,RunStatsCompressorHwc,compressor runtime in min and starts in Hwc mode,,,,1802,,,IGN:1;minutes4:runtime;cntstarts:cycles,,,,,,,,,,,,,,,,,,,,,
!include,hcmode.inc,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,
!include,errors.inc,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,