Notifications
You must be signed in to change notification settings - Fork 1
/
Copy pathCabUtils.py
130 lines (114 loc) · 5.87 KB
/
CabUtils.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
# Python import
import math
# User Import
# ----------------------------------------------------------
# Job : Common utilitess used by Qlxxx modules
#
# Editor : aymhenry@gmail.com
# ----------------------------------------------------------
class CabUtils:
# ----------------------------------------------------------
# Job : Calculates the saturation Density of Water - denh2o
# Input : Input: TF........ Saturation Temperature(Deg F)
#
# Output : Output: RHOS...... Saturation Density(#/ft3)
# ----------------------------------------------------------
def getSatWaterDensity(self, TF):
return 1.677 * self.getSatWaterPressure(TF) / (TF + 460.0)
# ----------------------------------------------------------
# Job : Calculates the Humidity Ratio of Air - humrat
# Input : Input: TF........ Saturation Temperature(Deg F)
# RELHUM...... Relative Humidity
# Output : Output: Humidity Ratio
# ----------------------------------------------------------
def getAirHumidity(self, TF, RELHUM):
PG = RELHUM * self.getSatWaterPressure(TF)
return 0.622 * PG/(14.7 - PG)
# ----------------------------------------------------------
# Job : Calculates the saturation pressure of Water satps
#
# Input : Input: TF...... Saturation Temperature(Deg F)
# Output : Output: PS...... Saturation Pressure(PSIA)
# ----------------------------------------------------------
def getSatWaterPressure(self, flt_tf):
TR = flt_tf + 460.0
return math.exp((-9560.8) / TR + 17.0234)
# ----------------------------------------------------------
# Job : Calculates the Enthalpy Change of Moist Air hwtair
# Input: TF1Start Temperature(Deg F)
# TF2 Final Temperature(Deg F)
# TFCAB Final Cabinet Temperature(Deg F)
# W1 Start Humidity Ratio
# W2 Final Humidity Ratio
#
# Output: HVAPS Sensible Enthalpy Change of the Air/Water Mixture assuming the water remains vapor(BTU/lb)
# HVAPL Latent Enthalpy Change of the Air/Water Mixture assuming the water remains vapor(BTU/lb)
# HLIQS Sensible Enthalpy Change of the Air/Water Mixture assuming the water condenses as liquid(BTU/lb)
# HLIQL Latent Enthalpy Change of the Air/Water Mixture assuming the water condenses as liquid(BTU/lb)
# HSLDS Sensible Enthalpy Change of the Air/Water Mixture assuming the water condenses as ice(BTU/lb)
# HSLDL Latent Enthalpy Change of the Air/Water Mixture assuming the water condenses as ice(BTU/lb)
#
# list [HVAPS, HVAPL, HLIQS, HLIQL, HSLDS, HSLDL]
# ----------------------------------------------------------
def getAirMoistEnthalpy(self, TF1, W1, TF2, W2, TFCAB):
PNDH2O = W1 - W2
if PNDH2O < 0.0:
W1 = W2
HVAPS = 0.24 * TF1 + W1 * (0.444*TF1) - 0.24 * TFCAB - W1 * (0.444*TFCAB)
HVAPL = 0.0
HLIQS = HVAPS + PNDH2O * 0.444 * (TFCAB - TF2)
HLIQL = PNDH2O * (1061.0 + 0.444 * TFCAB)
HSLDS = HLIQS
HSLDL = PNDH2O * ((1061.0 + 0.444 * TFCAB) + (158.9 - 0.488*TF2))
return [HVAPS, HVAPL, HLIQS, HLIQL, HSLDS, HSLDL]
# ----------------------------------------------------------
# Job : determine surface temperatures of cabinet walls
# R3 is not used in equation, not like FORTRAN commenter.
# T3F, E1, E2, A3 is not used
# Input : R1, R2, T1F, T2F, TF
# Output : updates Cab.Q, Cab.TF , Cab.Q2, Cab.Q, Cab.Q3 i.e. Q, TF, Q3, Q2
# return list [Q, TF]
# Input
# R1 is the resistance of refrigerator wall and inside wall heat trans
# R2 is the outside wall forced convection heat transfer
# R3 is the radiative heat transfer from the outside wall to the walls of
# the room the refrigerator is in.
# T1F is the inside refrigerator temperature(F)
# T2F is the outside ambient air temperature(F)
# T3F is the outside radiative temperature(F)
#
# Output
# E1 is the emissivity of the refrigerator outer wall
# E2 is the emissivity of the wall the refrigerator radiates to
# A3 is the wall area of the refrigerator that is radiating
# Q is the heat gain(if <0 the heat loss) of the refrigerator wall(BTU/hr)
# TF is the refrigerator outer wall surface temperature(F)
# Outer
# Wall
# Radiative
# T3---- Q3 ----[ Conduction ]
# [---- Q1 ----] Inner Wall Surface
# T2---- Q2 ----[ ]
# Forced Conv T T1
#
# Q1 = Q2 + Q3 The heat thru the wall(Q1) must equal the
# heat removed thru radiation(Q3) and forced
# convection(Q2) which act in parallel.
#
# Q1 = (T - T1) /R1
# Q2 = (T2 - T) /R2
# Q3 = (T3 - T) /R3
#
# Modified to ignore radiation transfer.
# It is assumed that the convective heat transfer will cover all situations
# (i.e. the radiative component is part of the convection coefficient
#
# ----------------------------------------------------------
def getRadHeatFlux(self, R1, R2, T1F, T2F):
TF = (R2 * T1F + R1 * T2F) / (R1 + R2)
Q = (TF - T1F) / R1
# Q2 = Q # same as FORTRAN code
# Q3 = 0.0# same as FORTRAN code
return [Q, TF]
# .=.=.=.=.=.=.=.=.=.=.=.=.=.=.=.=.=.=.==.=.=.=.=.=.=.=.=.=.=.=.=.=.=.=.=.=.=.=.=.=.=.=.=.=.=.=
# ___________ End of Cab class _________________________________________________________________