Expand 10 Click demo application is developed using the NECTO Studio, ensuring compatibility with mikroSDK's open-source libraries and tools. Designed for plug-and-play implementation and testing, the demo is fully compatible with all development, starter, and mikromedia boards featuring a mikroBUS™ socket.
- Author : Stefan Filipovic
- Date : Aug 2021.
- Type : I2C type
This example demonstrates the use of Expand 10 Click board.
- MikroSDK.Board
- MikroSDK.Log
- Click.Expand10
expand10_cfg_setup
Config Object Initialization function.
void expand10_cfg_setup ( expand10_cfg_t *cfg );
expand10_init
Initialization function.
err_t expand10_init ( expand10_t *ctx, expand10_cfg_t *cfg );
expand10_default_cfg
Click Default Configuration function.
err_t expand10_default_cfg ( expand10_t *ctx );
expand10_set_pin_direction
This function sets the direction of the selected pins.
err_t expand10_set_pin_direction ( expand10_t *ctx, uint8_t direction, uint8_t port, uint8_t pin_mask );
expand10_set_pin_value
This function sets the value of the selected pins.
err_t expand10_set_pin_value ( expand10_t *ctx, uint8_t port, uint8_t clr_mask, uint8_t set_mask );
expand10_read_port_value
This function reads the value of the selected port input pins.
err_t expand10_read_port_value ( expand10_t *ctx, uint8_t port, uint8_t *data_out );
Initializes the driver and performs the Click default configuration which sets the first two ports as output and the third port as input with pull-down enabled.
void application_init ( void )
{
log_cfg_t log_cfg; /**< Logger config object. */
expand10_cfg_t expand10_cfg; /**< Click config object. */
/**
* Logger initialization.
* Default baud rate: 115200
* Default log level: LOG_LEVEL_DEBUG
* @note If USB_UART_RX and USB_UART_TX
* are defined as HAL_PIN_NC, you will
* need to define them manually for log to work.
* See @b LOG_MAP_USB_UART macro definition for detailed explanation.
*/
LOG_MAP_USB_UART( log_cfg );
log_init( &logger, &log_cfg );
log_info( &logger, " Application Init " );
// Click initialization.
expand10_cfg_setup( &expand10_cfg );
EXPAND10_MAP_MIKROBUS( expand10_cfg, MIKROBUS_1 );
err_t init_flag = expand10_init( &expand10, &expand10_cfg );
if ( I2C_MASTER_ERROR == init_flag )
{
log_error( &logger, " Application Init Error. " );
log_info( &logger, " Please, run program again... " );
for ( ; ; );
}
init_flag = expand10_default_cfg ( &expand10 );
if ( EXPAND10_ERROR == init_flag )
{
log_error( &logger, " Default Config Error. " );
log_info( &logger, " Please, run program again... " );
for ( ; ; );
}
log_info( &logger, " Application Task " );
}
Sets the pins of the first two ports and then reads and displays the status of all ports on the USB UART approximately once per second.
void application_task ( void )
{
uint8_t port_value = 0;
for ( uint16_t pin_num = EXPAND10_PIN_0_MASK; pin_num <= EXPAND10_PIN_7_MASK; pin_num <<= 1 )
{
expand10_set_all_pins_value( &expand10, pin_num );
expand10_read_port_value( &expand10, EXPAND10_PORT_0, &port_value );
log_printf( &logger, " Status P0 (output): 0x%.2X\r\n", ( uint16_t ) port_value );
expand10_read_port_value( &expand10, EXPAND10_PORT_1, &port_value );
log_printf( &logger, " Status P1 (output): 0x%.2X\r\n", ( uint16_t ) port_value );
expand10_read_port_value( &expand10, EXPAND10_PORT_2, &port_value );
log_printf( &logger, " Status P2 (input) : 0x%.2X\r\n\r\n", ( uint16_t ) port_value );
Delay_ms ( 1000 );
}
}
This Click board can be interfaced and monitored in two ways:
- Application Output - Use the "Application Output" window in Debug mode for real-time data monitoring. Set it up properly by following this tutorial.
- UART Terminal - Monitor data via the UART Terminal using a USB to UART converter. For detailed instructions, check out this tutorial.
The complete application code and a ready-to-use project are available through the NECTO Studio Package Manager for direct installation in the NECTO Studio. The application code can also be found on the MIKROE GitHub account.