BUCK 7 Click demo application is developed using the NECTO Studio, ensuring compatibility with mikroSDK's open-source libraries and tools. Designed for plug-and-play implementation and testing, the demo is fully compatible with all development, starter, and mikromedia boards featuring a mikroBUS™ socket.
- Author : MikroE Team
- Date : dec 2019.
- Type : SPI type
This demo application controls the voltage at the output using the BUCK 7 Click.
- MikroSDK.Board
- MikroSDK.Log
- Click.BUCK7
buck7_cfg_setup
Config Object Initialization function.
void buck7_cfg_setup ( buck7_cfg_t *cfg );
buck7_init
Initialization function.
err_t buck7_init ( buck7_t *ctx, buck7_cfg_t *cfg );
buck7_default_cfg
Click Default Configuration function.
void buck7_default_cfg ( buck7_t *ctx );
buck7_set_output_voltage
Function for settings output voltage.
void buck7_set_output_voltage ( buck7_t *ctx, uint16_t voltage );
buck7_enable
Function for enable chip.
void buck7_enable( buck7_t *ctx );
buck7_set_mode
Function for settings chip mode.
void buck7_set_mode( buck7_t *ctx, uint8_t mode );
Initializes Driver init, reset chip, enable chip and set mode
void application_init ( void )
{
log_cfg_t log_cfg;
buck7_cfg_t cfg;
/**
* Logger initialization.
* Default baud rate: 115200
* Default log level: LOG_LEVEL_DEBUG
* @note If USB_UART_RX and USB_UART_TX
* are defined as HAL_PIN_NC, you will
* need to define them manually for log to work.
* See @b LOG_MAP_USB_UART macro definition for detailed explanation.
*/
LOG_MAP_USB_UART( log_cfg );
log_init( &logger, &log_cfg );
log_info( &logger, "---- Application Init ----" );
// Click initialization.
buck7_cfg_setup( &cfg );
BUCK7_MAP_MIKROBUS( cfg, MIKROBUS_1 );
buck7_init( &buck7, &cfg );
buck7_enable( &buck7 );
buck7_set_mode( &buck7, BUCK7_MODE_PWM );
}
Sets output voltage to 5V, 10V, 15V, 20V, 25V every 3 seconds. It is necessary to set the input voltage on 2.7V + maximum output voltage.
void application_task ( )
{
buck7_set_output_voltage( &buck7, BUCK7_OUT_VOLTAGE_5V );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
buck7_set_output_voltage( &buck7, BUCK7_OUT_VOLTAGE_10V );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
buck7_set_output_voltage( &buck7, BUCK7_OUT_VOLTAGE_15V );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
buck7_set_output_voltage( &buck7, BUCK7_OUT_VOLTAGE_20V );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
buck7_set_output_voltage( &buck7, BUCK7_OUT_VOLTAGE_25V );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
buck7_set_output_voltage( &buck7, BUCK7_OUT_VOLTAGE_20V );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
buck7_set_output_voltage( &buck7, BUCK7_OUT_VOLTAGE_15V );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
buck7_set_output_voltage( &buck7, 0x0BB8 ); /* 10 V */
Delay_ms ( 1000 );
Delay_ms ( 1000 );
Delay_ms ( 1000 );
}
This Click board can be interfaced and monitored in two ways:
- Application Output - Use the "Application Output" window in Debug mode for real-time data monitoring. Set it up properly by following this tutorial.
- UART Terminal - Monitor data via the UART Terminal using a USB to UART converter. For detailed instructions, check out this tutorial.
The complete application code and a ready-to-use project are available through the NECTO Studio Package Manager for direct installation in the NECTO Studio. The application code can also be found on the MIKROE GitHub account.