Update or Refresh an enclosure.

SYNTAX

Update-HPOVEnclosure[ [-Refresh] <SwitchParameter>] [-InputObject] <Object> [-ApplianceConnection] <Array> [-Hostname] <String> [-Username] <String> [-Password] <String>[ [-Async] <SwitchParameter>][ [-WhatIf] <SwitchParameter>][ [-Confirm] <SwitchParameter>] [<CommonParameters>]
Update-HPOVEnclosure[ [-Reapply] <SwitchParameter>] [-InputObject] <Object> [-ApplianceConnection] <Array>[ [-Async] <SwitchParameter>][ [-WhatIf] <SwitchParameter>][ [-Confirm] <SwitchParameter>] [<CommonParameters>]

Detailed Description

This cmdlet will update or refresh an enclosure. An Enclosure Refresh will instruct HPE OneView to go inventory the enclosure and update any missing management configurations.

Use the -Refresh switch for scenarios where adding an enclosure results in a warning or critical error when a BL server cannot be managed due to an existing _HPOneViewAdmin account that cannot be reset or too many HP SSO Certificates are configured (iLO supports no more than 5) and you have manually cleared the HP SSO list and/or removed the _HPOneViewAdmin account.

Parameters

-ApplianceConnection <Array>

Aliases [-Appliance]

Specify one or more HPOneView.Appliance.Connection object(s) or Name property value(s). If Resource object is provided via Pipeline, the ApplianceConnection property of the object will be used.

Default Value: ${Global:ConnectedSessions} | ? Default

Aliases Appliance
Required? true
Position? named
Default value (${Global:ConnectedSessions} | ? Default)
Accept pipeline input? true (ByPropertyName)
Accept wildcard characters?    False

-Async <SwitchParameter>

Immediately return asyncronous task object to monitor.

Aliases None
Required? false
Position? named
Default value False
Accept pipeline input? false
Accept wildcard characters?    False

-Confirm <SwitchParameter>

Aliases cf
Required? false
Position? named
Default value
Accept pipeline input? false
Accept wildcard characters?    False

-Hostname <String>

When an Enclosure is in an Error state where the Primary Onboard Administrator IP Address changed, or the HPE OneView managed configuration is no longer present, you will need to provide the IP Address or FQDN of one of the Onboard Administrators in the target enclosure. You will be prompted for this value if needed.

Aliases None
Required? true
Position? named
Default value
Accept pipeline input? false
Accept wildcard characters?    False

-InputObject <Object>

Aliases [-Enclosure] Provide the Enclosure name or Object, or [System.Collections.ArrayList] of names or Objects to refresh/update.

Aliases Enclosure
Required? true
Position? named
Default value
Accept pipeline input? true (ByValue)
Accept wildcard characters?    False

-Password <String>

Provide the password of the Onboard Administrator administrator account to re-apply the configuration if the enclosure is in an error state and the HPE OneView managed configuration is no longer present. You will be prompted for this value if needed.

Aliases None
Required? true
Position? named
Default value
Accept pipeline input? false
Accept wildcard characters?    False

-Reapply <SwitchParameter>

Reapply the Enclosure Configuration.

Aliases None
Required? false
Position? named
Default value False
Accept pipeline input? false
Accept wildcard characters?    False

-Refresh <SwitchParameter>

Refresh the enclosure to fix configuration issues.

Aliases None
Required? false
Position? named
Default value False
Accept pipeline input? false
Accept wildcard characters?    False

-Username <String>

Provide the Username of an Onboard Administrator administrator account to re-apply the configuration if the enclosure is in an error state and the HPE OneView managed configuration is no longer present. You will be prompted for this value if needed.

Aliases None
Required? true
Position? named
Default value
Accept pipeline input? false
Accept wildcard characters?    False

-WhatIf <SwitchParameter>

Aliases wi
Required? false
Position? named
Default value
Accept pipeline input? false
Accept wildcard characters?    False

<CommonParameters>

This cmdlet supports the common parameters: Verbose, Debug, ErrorAction, ErrorVariable, WarningAction, WarningVariable, OutBuffer, PipelineVariable, and OutVariable. For more information, see about_CommonParameters (http://go.microsoft.com/fwlink/?LinkID=113216)

Input Types

System.Management.Automation.PSCustomObject Single Enclosure resource **System.Collections.ArrayList ** Multiple Enclosure resources

Return Values

HPOneView.Appliance.TaskResource [System.Management.Automation.PSCustomObject] Async task Resource object for monitoring the enclosure import process

Examples

 -------------------------- EXAMPLE 1 --------------------------

PS C:\> Get-HPOVEnclosure | Update-HPOVEnclosure -Refresh

Refresh all available enclosures, from all connected sessions.

 -------------------------- EXAMPLE 2 --------------------------

PS C:\> Get-HPOVEnclosure -Name Enclosure1 | Update-HPOVEnclosure -Refresh

Refresh 'Enclosure1' enclosure.

 -------------------------- EXAMPLE 3 --------------------------

PS C:\> $AsyncTaskToMonitor = Get-HPOVEnclosure -Name Enclosure1 | Update-HPOVEnclosure -Refresh -Hostname UpdatedOAFQDN.domain.local -Username Administrator -Password MyOAPassw0rd -Async

Refresh 'Enclosure1' enclosure, supplying the updated OA FQDN and administrator credentials

Related Links


### HPE OneView 2.00 Library

Update-HPOVEnclosure

Update or Refresh an enclosure.

SYNTAX

Update-HPOVEnclosure [-Enclosure] <Object> [-ApplianceConnection] <Object>[ [-Refresh] <SwitchParameter>][ [-Async] <SwitchParameter>][ [-WhatIf] <SwitchParameter>][ [-Confirm] <SwitchParameter>] [<CommonParameters>]
Update-HPOVEnclosure [-Enclosure] <Object> [-ApplianceConnection] <Object>[ [-Reapply] <SwitchParameter>][ [-Async] <SwitchParameter>][ [-WhatIf] <SwitchParameter>][ [-Confirm] <SwitchParameter>] [<CommonParameters>]

Detailed Description

This Cmdlet will update or refresh an enclosure. An Enclosure Refresh will instruct HPE OneView to go inventory the enclosure and update any missing management configurations.

Use the -Refresh switch for scenarios where adding an enclosure results in a warning or critical error when a BL server cannot be managed due to an existing _HPOneViewAdmin account that cannot be reset or too many HP SSO Certificates are configured (iLO supports no more than 5) and you have manually cleared the HP SSO list and/or removed the _HPOneViewAdmin account.

Parameters

-ApplianceConnection <Object>

Aliases [-Appliance]

Specify one or more HPOneView.Appliance.Connection object(s) or Name property value(s). If Resource object is provided via Pipeline, the ApplianceConnection property of the object will be used.

Default Value: ${Global:ConnectSessions}

Aliases Appliance
Required? true
Position? 1
Default value (${Global:ConnectedSessions} | ? Default)
Accept pipeline input? true (ByPropertyName)
Accept wildcard characters?    False

-Async <SwitchParameter>

Immediately return async task resource to be monitored.

Aliases None
Required? false
Position? named
Default value False
Accept pipeline input? false
Accept wildcard characters?    False

-Confirm <SwitchParameter>

Aliases cf
Required? false
Position? named
Default value
Accept pipeline input? false
Accept wildcard characters?    False

-Enclosure <Object>

Provide the Enclosure name, URI or Object, or [System.Array] of names, URIs or Objects to refresh/update.

Aliases None
Required? true
Position? 0
Default value
Accept pipeline input? true (ByValue)
Accept wildcard characters?    False

-Reapply <SwitchParameter>

Reapply the Enclosure Configuration.

Aliases None
Required? false
Position? named
Default value False
Accept pipeline input? false
Accept wildcard characters?    False

-Refresh <SwitchParameter>

Refresh the enclosure to fix configuration issues.

Aliases None
Required? false
Position? named
Default value False
Accept pipeline input? false
Accept wildcard characters?    False

-WhatIf <SwitchParameter>

Aliases wi
Required? false
Position? named
Default value
Accept pipeline input? false
Accept wildcard characters?    False

<CommonParameters>

This cmdlet supports the common parameters: Verbose, Debug, ErrorAction, ErrorVariable, WarningAction, WarningVariable, OutBuffer, PipelineVariable, and OutVariable. For more information, see about_CommonParameters (http://go.microsoft.com/fwlink/?LinkID=113216)

Input Types

System.Management.Automation.PSCustomObject Single Enclosure resource.

System.Array Multiple Enclosure resources.

Return Values

HPOneView.Appliance.TaskResource [System.Management.Automation.PSCustomObject] Async task Resource object for monitoring the enclosure import process.

Examples

 -------------------------- EXAMPLE 1 --------------------------

PS C:\> Update-HPOVEnclosure -Refresh

Refresh all available enclosures, from all connected sessions.

 -------------------------- EXAMPLE 2 --------------------------

PS C:\> Update-HPOVEnclosure Enclosure1 -Refresh

Refresh 'Enclosure1' enclosure.

Related Links


### HPE OneView 1.20 Library

Update-HPOVEnclosure

Update or Refresh an enclosure.

SYNTAX

Update-HPOVEnclosure[ [-Enclosure] <Enclosure>] [-Refresh] <Refresh>[ [-Monitor] <Monitor>] [<CommonParameters>]
Update-HPOVEnclosure[ [-Enclosure] <Enclosure>] [-Reapply] <Reapply>[ [-Monitor] <Monitor>] [<CommonParameters>]
Update-HPOVEnclosure[ [-Enclosure] <Enclosure>] [-UpdateFromEG] <UpdateFromEG>[ [-Monitor] <Monitor>] [<CommonParameters>]

Detailed Description

This cmdlet will update or refresh an enclosure. An Enclosure Refresh will instruct HP OneView to go inventory the enclosure and update any missing management configurations. An Enclosure Update from EG will re-apply the Enclosure Group configuration for compliance.

Use the -Refresh switch for scenarios where adding an enclosure results in a warning or critical error when a BL server cannot be managed due to an existing _HPOneViewAdmin account that cannot be reset or too many HP SSO Certificates are configured (iLO supports no more than 5) and you have manually cleared the HP SSO list and/or removed the _HPOneViewAdmin account.

Parameters

-Enclosure <Enclosure>

Optional. Provide the Enclosure name, URI or Object, or [System.Array] of names, URIs or Objects to refresh/update.

Aliases None.
Required? false
Position? 1
Default value
Accept pipeline input? true (ByValue)
Accept wildcard characters?    false

-Refresh <Refresh>

Refresh the enclosure to fix configuration issues.

Aliases None.
Required? true
Position? named
Default value False
Accept pipeline input? false
Accept wildcard characters?    false

-UpdateFromEG <UpdateFromEG>

Aliases [-update] Update the Enclosure configuration from the associated Enclosure Group.

Aliases None.
Required? true
Position? named
Default value False
Accept pipeline input? false
Accept wildcard characters?    false

-Reapply <Reapply>

Reapply the Enclosure Configuration.

Aliases None.
Required? true
Position? named
Default value False
Accept pipeline input? false
Accept wildcard characters?    false

-Monitor <Monitor>

Optional. Wait for the update task to complete.

Aliases None.
Required? false
Position? named
Default value False
Accept pipeline input? false
Accept wildcard characters?    false

<CommonParameters>

This cmdlet supports the common parameters: Verbose, Debug, ErrorAction, ErrorVariable, WarningAction, WarningVariable, OutBuffer, PipelineVariable, and OutVariable. For more information, see about_CommonParameters (http://go.microsoft.com/fwlink/?LinkID=113216)

Input Types

System.Management.Automation.PSCustomObject Single Enclosure resource. System.Array Multiple Enclosure resources.

Return Values

HPOneView.Appliance.TaskResource [System.Management.Automation.PSCustomObject] Async task Resource object for monitoring the enclosure import process.

Examples

 -------------------------- EXAMPLE 1 --------------------------

PS C:\> Update-HPOVEnclosure -Refresh

Refresh all available enclosures.

 -------------------------- EXAMPLE 2 --------------------------

PS C:\> Update-HPOVEnclosure Enclosure1 -Refresh

Refresh 'Enclosure1' enclosure.

 -------------------------- EXAMPLE 3 --------------------------

PS C:\> Update-HPOVEnclosure -UpdateFromEG

Re-apply Enclosure Group settings all available enclosures.

 -------------------------- EXAMPLE 4 --------------------------

PS C:\> Update-HPOVEnclosure Enclosure1 -UpdateFromEG

Re-apply Enclosure Group settings 'Enclosure1' enclosure.

Related Links


Wiki Table of Contents

Clone this wiki locally